Aim: This study aims to evaluate and compare the incidence of dentinal defects induced by Hand Files, HyFlex CM, ProTaper Next (PTN), and One Shape during canal preparation. Materials and Methods: One hundred and fifty extracted mandibular premolar teeth with single root canal were selected. Specimens were then divided into five groups with thirty specimens each. Group I: Specimens were prepared with hand instruments. Group II: Specimens were prepared with HyFlex CM rotary files (Coltene) using a crown-down technique according to the manufacturer's instructions. Group III: Specimens were prepared with PTN rotary files (Dentsply) using a crown-down technique according to the manufacturer's instructions. Group IV: Specimens were prepared with One Shape Single file rotary system (MicroMega) using a crown-down technique according to the manufacturer's instructions. Group V: Specimens were used as a control and left unprepared. All roots were cut horizontally at 3, 6, and 9 mm from the apex. Sections were then viewed under stereomicroscope and dentinal defects were registered as “no defect,” “fracture,” and “other defects.” Statistical Analysis: Results of the study were subjected to Chi-square test. Results: Results were expressed as the number and percentage of defected, partially defected and roots with no defects in each groups. Conclusion: Hand files and One Shape file system caused less root defects compared to PTN and HyFlex file systems.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed268    
    Printed27    
    Emailed0    
    PDF Downloaded37    
    Comments [Add]    

Recommend this journal